In order to facilitate this exchange of warm and cool air the general rule of thumb suggests installing at least 1 sq.
Roofing ventilation requirements in westminister.
Let owens corning roofing help you calculate exactly how much ventilation you will need for a healthy and balanced attic with our 4 step ventilation calculator.
Contact your building department to learn about the requirements for low slope applications.
For buildings under 25 000 square feet square footage of the entire building as defined in the green buildings ordinance.
Federal housing authority recommends a minimum of at least 1 square foot of attic ventilation evenly split between intake and exhaust for every 300 square feet of attic floor space.
In such cases the effective rate of ventilation per person can also be increased by limiting the number of people present in the building in general or in specific rooms.
Balanced ventilation is achieved when intake and exhaust allow for same amount of airflow because the natural forces of air pressure create a push pull effect around your roof.
The amount of space you devote to intake must be equal to the amount you allow for exhaust and these must be calculated according to the size of your attic and slope of your roof.
When a roofing permit is needed for roof repairs.
According to their requirements you should have 1 square foot of attic ventilation per 300 sq ft of attic floor space.
What if my roof slope is less than 4 12.
Westminster colorado roofing codes.
Roofing contractors and hail damage roof inspectors can access the westminster colorado roofing codes for residential roof repair and roof replacement projects as well as commercial roof repair and replacement projects.
You can calculate attic ventilation requirements by determining the square footage of your attic.
The key to proper ventilation of your roof and attic is balance.
In order for attic ventilation to work effectively however the ventilation system must have balanced intake and exhaust.
Enter square footage calculate or enter the square footage of the attic or area to be vented.
Of vent for every 300 sq.
Level of the new roof and replaced if they are in poor condition badly rusted or otherwise deteriorated.
Building codes vary.
The federal housing authority fha and the urban development hud have established minimum requirements for attic ventilation.
This handout addresses the frequently asked questions regarding re roofing and to list the typical.
For all permits issued after september 12 2016 the effective code is 2016 dbca 2015 ibc 2015 irc.
If your roof is 1200 sq ft soffit floor space you will need 4 sq feet of roof ventilation.
There should also be a 50 50 balance of attic venting and roof venting.